International Journal of Experimental Dental Science

Register      Login

VOLUME 9 , ISSUE 2 ( July-December, 2020 ) > List of Articles

RESEARCH ARTICLE

Evaluation of Evaporation Effect on the Film Thickness of Two Commercially Available Die Spacers on Three Different Surfaces

Dinesh Kumar, Ranjoy Hazara, Ayush Srivastav

Citation Information : Kumar D, Hazara R, Srivastav A. Evaluation of Evaporation Effect on the Film Thickness of Two Commercially Available Die Spacers on Three Different Surfaces. Int J Experiment Dent Sci 2020; 9 (2):47-51.

DOI: 10.5005/jp-journals-10029-1211

License: CC BY-NC 4.0

Published Online: 01-12-2020

Copyright Statement:  Copyright © 2020; The Author(s).


Abstract

The present study was done to evaluate the effect of evaporation on the film thickness of two commercially available die spacers on three different surfaces. Die spacers used were Nice Fit and Durolan. Both die spacers were applied on three different surfaces—glass slide, die stone slab without hardener, and die stone slab with hardener after the bottles were left open for 0, 2, 4, 8, and 12 hours. The film thickness was measured with the help of SEM. Nice Fit die spacer showed an increase of 53, 139.5, 159.6, and 190.9% and Durolan showed an increase in 45.3, 142.6, 181.9, and 200% for 2, 4, 8, and 12 hours, respectively. Therefore, the number of coats must be reduced to achieve an ideal die spacer film thickness in the range of 25–40 μm. The thickness of die spacer on die stone slab without hardener was more compared to that on glass slide and on die stone slab coated with a hardener.


HTML PDF Share
  1. Campagni WV, Wright W, Martinoff JT. Effect of die spacer on the seating of complete cast gold crowns with grooves. J Prosthet Dent 1986;55(3):324–328. DOI: 10.1016/0022-3913(86)90112-5.
  2. Hager TS, Gardner FM, Edge MJ. The effect of selective die spacer placement techniques on the seatability of castings. J Prosthet Dent 1993;2(1):56–60. DOI: 10.1111/j.1532-849X.1993.tb00382.x.
  3. Dixon DL, Breeding LC, Lilly KR. Use of luting agents with an implant system: Part II. J Prosthet Dent 1992;68(4):885–889. DOI: 10.1016/0022-3913(92)90544-K.
  4. Grajower R, Zuberi, Lewinstein I. Improving the fit of crowns with die spacers. J Prosthet Dent 1989;61(5):555–563. DOI: 10.1016/0022-3913(89)90275-8.
  5. Gegauff AG, Rosenstiel SF. Reassessment of die-spacer with dynamic loading during cementation. J Prosthet Dent 1989;61(6):655–658. DOI: 10.1016/S0022-3913(89)80036-8.
  6. Oliva RA, Lowe JA, Ozaki MM. Film thickness measurements of a paint-on die spacer. J Prosthet Dent 1988;60(2):180–184. DOI: 10.1016/0022-3913(88)90312-5.
  7. Psillakis JJ, Mc Alarney ME, Wright RF, et al. Effect of evaporation and mixing technique on die spacer thickness. J Prosthet Dent 2001;85(1):82–87. DOI: 10.1067/mpr.2001.113028.
  8. Psillakis J, Mc Alarney M, Wright R, et al. Effect of evaporation and mixing technique on die spacer thickness: a preliminary study. J Prosthet Dent 2002;87(2):132–138. DOI: 10.1016/S0022-3913(02)70088-7.